According to Decision No. 04/2017/QD-TTG, a number of devices are required and voluntary to be labeled with energy before being circulated on the market, specifically as follows:
List of mandatory energy labeling products: Straight tube fluorescent lamps, compact fluorescent lamps, electromagnetic and electronic ballasts for fluorescent lamps, air conditioners, rice cookers, electric fans, refrigerators, machines washing machines, television sets, three-phase distribution transformers, electric motors, commercial refrigerators.
List of voluntary energy labels: Copiers, computer monitors, printers
List of applicable products with energy efficiency labeling and applicable standards
| No | Group | Product name | Classification | Standard |
| 1 | Household Appliance | LED Lighting | Compact Fluorescent Lamps (CFL) power range of 5 W to 60 W, integrated electronic ballasts |
TCVN 7896:2015 |
| Electronic ballasts for fluorescent lamps use with AC mains, voltage up to 1000 V, frequency 50 Hz or 60 Hz, for fluorescent lamp(s) between 4 W and 65 W. |
TCVN 7897:2013 TCVN 8248:2013 |
|||
| Linear Tubular Fluorescent Lamp (LTFL) power range of power from 4 W to 65 W, for use with all three 50 Hz and three high frequency slices connected to the mains mains rated voltage 220 V |
TCVN 8249:2013 | |||
| LED Lamp with E27 and B22 caps and double-ended LED lamps intended to replace conventional fluorescent lamps. tubes with G5 AND G13 caps, for general use, having a capacity of up to 60 W, rated voltage not exceeding 250 V. | TCVN 11844:2017 | |||
| 2 | Electric fans | –Table fans, – Floor fans, – Wall fans, – Window fans, – Ceiling fans, – Roof fans, with an attached electric motor with a capacity not exceeding 125 W |
TCVN 7826:2015 | |
| 3 | Refrigerators | Tủ lạnh, tủ kết đông lạnh có dung tích đến 1000L, được làm lạnh bằng đối lưu tự nhiên hoặc lưu thông không khí cưỡng bức. | TCVN 7828:2016 | |
| 4 | Air conditioner | – Ceiling mounted air conditioners, – Wall mounted air conditioners, – Ducted air conditioners (nominal cooling capacity is less than 8000 W). |
TCVN 7830:2015 | |
| 5 | Household washing machines | Washing machine with or without cold water heating equipment and/or heater, rated capacity from 2kg to 15kg, using AC power, supply 220V, frequency 50Hz. | TCVN 8526:2013 | |
| 6 | Television sets | - TV/VCR, - TV/DVD, - TV/VCR/DVD combo sets television sets with a rated power of less than 1000W |
TCVN 9536:2012 | |
| 7 | Rice cookers | Rice cookers with a rated power up to 2000W | TCVN 8252:2015 | |
| 8 | Reserved water heaters | Capacity up to 50 liter | TCVN 7898:2018 | |
| 1 | Office and commercial equipment | Computer monitors | consisting of a display screen and associated electronic circuit, normally installed in an enclosure unique, capable of displaying visual information from a computer through one or more inputs | TCVN 9508:2012 |
| 2 | Notebooks | Notebooks covered by this standard are computers defined in section 4.1.2. | TCVN 11848:2017 | |
| 3 | Printers | – This standard applies to standard format printers – This standard applies to equipment that performs multiple functions of copiers, fax machines and scanners. |
TCVN 9509:2012 | |
| 4 | Copiers | - Máy photocopy có định dạng chuẩn - Thiết bị thực hiện nhiều chức năng như chức năng của máy in, máy fax và máy quét. |
TCVN 9510:2012 | |
| 5 | Commercial Refrigerator | Commercial Refrigerator for sale and display of food | TCVN 10289:2014 | |
| 1 | Industrial equipment | Electric motor | Asynchronous, three phase, squirrel cage rotor, single speed, using a power supply frequency of 50Hz and/or 60 Hz and: – With rated voltage UN up to 1000V; – With a rated output power PN from 0.75 kW to 150 kW; – With 2, 4 or 6 poles – Operation in S1 mode (continuous mode) – Work directly on the grid; Motors equipped with removable gearboxes or braking devices are also covered by this standard, although special shafts and flanges may be used in these engines |
TCVN 7540-1:2013 |
| 2 | Transformers | Distribution 3 phase transformer (immersion in oil). | TCVN 8525:2010 | |
| 3 | Boilers | Types of boilers in use, the mass and calorific value of fuel used can be determined. | TCVN 8630:2010 |
Energy labeling records include:
- Energy label announcement paper according to regulations of the Ministry of Industry and Trade
- Energy efficiency test results
- Expected energy label template
- Documents proving that the foreign testing laboratory has met the conditions (For the case where the energy labeling test is performed by a foreign testing organization);
Energy labeling process
Step 1: Test samples at domestic testing organizations that meet the provisions of Chapter II of Decree No. 107/2016/ND-CP or foreign testing organizations accredited by ISO/IEC 17025 (or equivalent) by accreditation bodies that have signed mutual recognition agreements (ILAC or APLAC).
Step 2: Submit the application for energy labeling to the Ministry of Industry and Trade Enterprises applying for energy labeling can choose to submit their dossiers via the internet at the website of the Ministry of Industry and Trade or send their dossiers directly or by post to the Ministry of Industry and Trade.
Step 3: After submitting the application for registration of energy labeling to the Ministry of Industry and Trade, the enterprise is entitled to self-label the energy in accordance with the information in the Declaration of energy labeling for the registered product.
For detailed advice, please contact email: info@dtnc.vn or hotline: (+84) 86 261 9168