What is Ingress Protection (IP) testing?
The IP test is intended to test the degree of protection an enclosure is capable of with varying degrees of solid (dust) or liquid (water) ingress.
In other words, IP is an international standard parameter for the level of dust and water resistance that the device achieves. Following the lowercase IP letter with two digits to show the level of protection of the device against external factors, so that customers feel more secure during use without worrying about damage. not quality.
The IP number on the device has a different meaning depending on the two following digits. The higher the IP rating, the better the protection of the device against the effects of dust and water. As follows:
IPXY:
- X: is the character indicating the degree of protection against dust
- Y: is the character indicating the degree of protection against water

Today's popular IP standard
1. Dustproof standard
| IP | Degree of Protection | Object Size |
| 0 | No protection | Can't measure |
| 1 | Protects against large surfaces of objects such as hands when in contact with the device (not fingernails or fingers) | Less than 50mm |
| 2 | Protection when in contact with small surfaces of objects such as fingers, nails.. or similar objects | Less than 12.5mm |
| 3 | Protect from tools and thick wires or similar objects | Less than 2.5mm |
| 4 | Protection from most wires, screws or other similar objects | Less than 1mm |
| 5 | Partial protection from harmful dust on contact | Can't measure |
| 6 | Full protection against harmful dust on contact | Can't measure |
2. Waterproof standard
| IP | Degree of Protection | Description | Testing |
| 0 | No protection | ||
| 1 | Anti-drip water | Requires equipment to be tested (EUT) free of harmful effects from dripping water | 10 minutes and the amount of water is equivalent to 1mm of rainfall per minute |
| 2 | Anti-drip when tilted 15° | The EUT shall not have harmful effects when the enclosure is tilted at an angle of 15° from the normal position of the sample in contact with dripping water. | 10 minutes and the amount of water is equivalent to 3mm of rainfall per minute |
| 3 | Anti-water spray |
The test specimen shall not have a double effect when sprayed at an angle of up to 60° to the vertical. Spray flow 0.7L/min per hole Ø0.4mm. Water pressure: 80kpa
|
10 minutes |
| 4 | Anti splash water |
The EUT shall not have a double effect when injected from all directions. Water flow rate 10 L/min and water pressure 80-100 kN/m².
|
At least 5 minutes |
| 5 | Anti-pressure water jet | The EUT shall not have a double effect when pressurized from all directions. With a nozzle diameter of 6.3mm with a water flow rate of 12.5L/min and a water pressure of 30 kN/m² (4.4 psi) at a distance of 3m. | At least 3 minutes |
| 6 | High pressure water jet resistance |
The test piece shall not have a double effect when pressurized from all directions. With a nozzle diameter of 12.5 mm with a water flow of 100L/min and a water pressure of 100 kN/m² (15psi) at a distance of 3m. |
At least 3 minutes |
| 7 | Resistant to 1m deep water immersion | The specimen shall not have a double effect when immersed in water 1 m below the lowest point of the specimen or the highest point 0.15 m below the surface, whichever is deeper. | 30 minutes |
| 8 | Resistant to immersion in water deeper than 1m | The test specimen shall not have a double effect when immersed in water more than 1 m deep than the lowest point of the test piece. Manufacturers specify the depth is usually 3m. | Depends on the manufacturer |
| 9 | Resistant to high pressure water spray, high temperature | Smaller samples rotate slowly on the turntable, from 4 specific angles. Larger test pieces are mounted in their intended position in use, without the need for a turntable and tested freely for at least 3 min at a distance of 0.15–0.2 m, flow rate 14–16 L/min, pressure 8–10 MPa (80–100 bar). The water temperature is 80°C. | 30 seconds in each of the 4 corners (2 minutes total) |
The following is a list of brief descriptions of IPX7 and IPX8 related tests:
| IP | Degree of protection against dust | Degree of protection against water |
| 08 | No protection | Soak more than 1m |
| 18 | Solid objects > 50mm | Soak more than 1m |
| 28 | Solid objects > 12.5mm | Soak more than 1m |
| 38 | Solid objects > 2.5mm | Soak more than 1m |
| 48 | Solid objects > 1mm | Soak more than 1m |
| 58 | Dustproof | Soak more than 1m |
| 68 | Dustproof | Soak more than 1m |
| 07 | No protection | Soak up to 1m |
| 17 | Solid objects > 50mm | Soak up to 1m |
| 27 | Solid objects > 12.5mm | Soak up to 1m |
| 37 | Solid objects > 2.5mm | Soak up to 1m |
| 47 | Solid objects > 1mm | Soak up to 1m |
| 57 | Dustproof | Soak up to 1m |
| 67 | Dustproof | Soak up to 1m |